queston from the multimeter retarded



duty cycle is on a 100% scale
i think the dwell scale is dependent on the engine, 90 for ours
if you want to use a plain meter to read the duty cycle, you can measure the
voltage in dc mode. since the meter takes the dc average, you will come up
with the average voltage applied. this is compared to the max applied
(probably 5 or 12 volts), can also be found by measuring ac volts in some
circuits.
example: if the circuit goes between 0 and 10 volts and you measure 7 VDC,
you have a 70% duty cycle.
hth
Al

----- Original Message -----
From: "calimus" <calimus@techography.net>
To: "Scirocco-l" <scirocco-l@scirocco.org>
Sent: Saturday, December 28, 2002 4:08 PM
Subject: queston from the multimeter retarded


> I'm looking to setting the air/fule mix on to JH 8v's and I don't know how
> to set a multimeter to read duty cycle.  Can anyone shed some light on
this
> for me?
>
> William
>
>
>
> _______________________________________________
> Scirocco-l mailing list
> Scirocco-l@scirocco.org
> http://neubayern.net/mailman/listinfo/scirocco-l
>